ACCU-ANSWER · Multi-Monitoring Meter

LBM-01

Four-parameter in-vitro monitoring of blood glucose, hemoglobin, total cholesterol, and uric acid in fresh capillary whole blood and venous whole blood.

Test parameters
4
Test time
5–15 s
Stored test results
400

Quickly Learn About the Product

Product Highlights

LBM-01 features: optional Bluetooth connection, strip ejection, quick results, multilingual app, risk warning, 400 test memories, small blood sample, CE and ISO symbols, auto-recognition strip, automatic on and off

Learn More Detailed Information About the Product

Instrument specifications

Blood glucose

Measuring speed5 seconds
Test principleElectrochemical biosensor
Measuring range20–600 mg/dL (1.10–33.30 mmol/L)
Sample volumeApproximately 1.5 µL
Sample typeCapillary whole blood and venous whole blood
Hematocrit range25–55%
AccuracyFulfils the requirements of EN ISO 15197:2015 / ISO 15197:2013

Hemoglobin

Measuring speed5 seconds
Test principleElectrochemical biosensor
Measuring range5.00–26.00 g/dL (3.10–16.15 mmol/L)
Sample volumeApproximately 1.5 µL
Sample typeCapillary whole blood and venous whole blood
Hematocrit range/
Accuracy/

Total cholesterol

Measuring speed15 seconds
Test principleElectrochemical biosensor
Measuring range100–400 mg/dL (2.58–10.34 mmol/L)
Sample volumeApproximately 3.0 µL
Sample typeCapillary whole blood and venous whole blood
Hematocrit range30–55%
Accuracy/

Uric acid

Measuring speed5 seconds
Test principleElectrochemical biosensor
Measuring range1.50–19.83 mg/dL (90–1190 µmol/L)
Sample volumeApproximately 1.5 µL
Sample typeCapillary whole blood and venous whole blood
Hematocrit range30–55%
Accuracy/

Packaging

Quantity per carton40 sets
Gross weight13.5 kg
Net weight12.5 kg
Carton dimensions60 × 35 × 30 cm

Intend use

The ACCU-ANSWER® isaw® Multi-Monitoring Meter is intended for the quantitative measurement of total cholesterol, blood glucose, hemoglobin, and uric acid in fresh capillary whole blood and venous whole blood.

Test results for total cholesterol, blood glucose, hemoglobin, and uric acid are plasma-calibrated. This helps you and your healthcare professional compare meter results with laboratory tests.

Learn How to Use the Product Correctly

Instructions for Use

LBM-01 procedure: insert strip, match the code number, apply blood sample, read the result, and eject the used strip

Supplementary material

Before you test

LBM-01 tips: match the meter and test-strip vial codes; squeeze out at least 5 µL of blood before applying a total cholesterol sample