ACCU-ANSWER · Multi-Monitoring Meter

LBM-02

A multi-parameter in-vitro monitoring system for triglycerides, total cholesterol, HDL-C, LDL-C, blood glucose, urine glucose, uric acid, urine uric acid, and hemoglobin.

Test parameters
9
Test time
5–15 s
Test data storage
Unlimited

Learn More Detailed Information About the Product

Instrument specifications

Triglycerides

Measuring range44–1062 mg/dL (0.50–12.00 mmol/L)
Reference range≤150 mg/dL (≤1.70 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

Total cholesterol

Measuring range19–387 mg/dL (0.50–10.00 mmol/L)
Reference range≤200 mg/dL (≤5.20 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

HDL-C

Measuring range19–97 mg/dL (0.50–2.50 mmol/L)
Reference range≥40 mg/dL (≥1.04 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

LDL-C

Measuring range58–251 mg/dL (1.50–6.50 mmol/L)
Reference range≤121 mg/dL (≤3.12 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

Blood glucose

Measuring range20–600 mg/dL (1.10–33.30 mmol/L)
Reference rangeFasting: 70–110 mg/dL (3.90–6.10 mmol/L); postprandial: <140 mg/dL (<7.80 mmol/L)
Test time5 seconds
Sample volume3 µL
Hematocrit25–55%

Urine glucose

Measuring range0–600 mg/dL (0–33.30 mmol/L)
Reference range≤100 mg/dL (≤5.55 mmol/L)
Test time10 seconds
Sample volume3 µL
Hematocrit/

Uric acid

Measuring range1.50–19.83 mg/dL (90–1190 µmol/L)
Reference rangeMale: 2.45–7.00 mg/dL (147–420 µmol/L); female: 1.47–5.95 mg/dL (88–357 µmol/L)
Test time5 seconds
Sample volume4 µL
Hematocrit30–55%

Urine uric acid

Measuring range8–202 mg/dL (0.50–12.00 mmol/L)
Reference range37–92 mg/dL (2.20–5.48 mmol/L)
Test time5 seconds
Sample volume4 µL
Hematocrit/

Hemoglobin

Measuring range5.00–27.00 g/dL (50.0–270.0 g/L; 3.1–16.77 mmol/L)
Reference rangeMale: 13.00–18.00 g/dL (130.0–180.0 g/L; 8.07–11.18 mmol/L); female: 11.50–16.50 g/dL (115.0–165.0 g/L; 7.14–10.25 mmol/L)
Test time5 seconds
Sample volume4 µL
Hematocrit/

Packaging

Quantity per carton25 sets
Gross weight15 kg
Net weight14 kg
Carton dimensions46 × 46 × 39 cm

Intend use

ACCU-ANSWER® isaw® Multi-Monitoring system is intended to be used for quantitative measurement of triglycerides, total cholesterol, IDL-C (low density lipoprotein cholesterol), blood glucose, uric acid, hemoglobin in fresh capillary whole blood or venous whole blood and urine glucose and urine uric acid in human urine. Estimated values of HDL-C (high density lipoprotein cholesterol) are calculated by the ACCU-ANSWER® isaw® Multi-Monitoring Meter. This system is valuable tool in monitoring diabetes, cholesterol levels, uric acid levels and hemoglobin levels, but it is not intended to diagnose diabetes, gout and anemia or cholesterol-related cases.