ACCU-ANSWER · Multi-Monitoring Meter

LBM-05

Multi-parameter monitoring system for lipid markers, blood glucose, hemoglobin and uric acid. Each measurement uses its corresponding test strip; standalone total cholesterol uses a different strip from the multi-marker lipid panel. Test ranges, times and sample volumes vary by test item.

Test parameters
7
Test time
5–15 s
Sample volume
1.5–13 µL

Use the matching test strip for each measurement. The four detailed lipid parameters share one strip; standalone total cholesterol, blood glucose and uric acid use their corresponding strips.

Instrument Specifications

Triglycerides

Measuring range44–1062 mg/dL (0.50–12.00 mmol/L)
Reference range≤150 mg/dL (≤1.70 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

Total cholesterol

Measuring range19–387 mg/dL (0.50–10.00 mmol/L)
Reference range≤201 mg/dL (≤5.20 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

HDL-C

Measuring range19–97 mg/dL (0.50–2.50 mmol/L)
Reference range≥40 mg/dL (≥1.04 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

IDL-C

Measuring range58–251 mg/dL (1.50–6.50 mmol/L)
Reference range≤121 mg/dL (≤3.12 mmol/L)
Test time15 seconds
Sample volume13 µL
Hematocrit30–55%

Blood glucose

Measuring range20–600 mg/dL (1.10–33.30 mmol/L)
Reference rangeFasting: 70–110 mg/dL (3.90–6.10 mmol/L); postprandial: less than 140 mg/dL (less than 7.80 mmol/L)
Test time5 seconds
Sample volume1.5 µL
Hematocrit25–55%

Hemoglobin

Measuring range5.00–26.00 g/dL (50.0–260.0 g/L or 3.1–16.15 mmol/L)
Reference rangeMale: 13.00–18.00 g/dL (130.0–180.0 g/L or 8.07–11.18 mmol/L); female: 11.50–16.50 g/dL (115.0–165.0 g/L or 7.14–10.25 mmol/L)
Test time5 seconds
Sample volume1.5 µL
Hematocrit/

Uric acid

Measuring range1.50–19.83 mg/dL (90–1190 µmol/L)
Reference rangeMale: 2.45–7.00 mg/dL (147–420 µmol/L); female: 1.47–5.95 mg/dL (88–357 µmol/L)
Test time5 seconds
Sample volume1.5 µL
Hematocrit30–55%

Total cholesterol (single-analyte test)

Test parameterTotal cholesterol
Measuring range100–400 mg/dL (2.58–10.34 mmol/L)
Reference range≤201 mg/dL (≤5.20 mmol/L)
Test time15 seconds
Sample volume3 µL
Hematocrit30–55%

Packaging

Package/

Intend use

The ACCU-ANSWER isaw® Multi-Monitoring Meter is intended to be used in conjunction with the accompanying test strips for in vitro quantitative determination of glucose concentration, uric acid concentration, hemoglobin concentration, total cholesterol concentration, and the four lipid components (total cholesterol, triglycerides, high-density lipoprotein cholesterol, and low-density lipoprotein cholesterol) in fresh capillary whole blood and venous whole blood. It also calculates non-high-density lipoprotein cholesterol. Clinically, it is mainly used for the auxiliary diagnosis of sugar metabolism diseases, hyperuricemia, anemia, hypercholesterolemia, and hypertriglyceridemia. The test results should not be used as the final clinical diagnosis.